Lifeline View AED
Meet the AED that's taking easy-to-use to a whole new level. Other AEDs tell you what to do in an emergency. The Lifeline VIEW is the first and only one that shows you--with video in full-motion color. With award-winning design, durability and easy maintenance - backed by the Defibtech commitment to innovation and excellence - we can guarantee you've never seen an AED like this before.
Tech Specs
Defibrillator
TYPE
Semi-Automatic external defibrillatorMODEL
DDU-2300 seriesWAVEFORM
Biphasic Truncated Exponential
(Impedance compensated)ENERGY
Adult: 150 Joules
Child / Infant: 50 Joules
(Nominal into 50 Ohm load)CONTROLS
Lighted On/Off button
Lighted Shock buttonCHARGE TIME *
Less than 4 seconds
(shock decision to shock)DISPLAY
High-resolution color LCDVIDEO PROMPTS
Full motion video
On-screen text promptsCPR COACHING
Video and voice coaching
On-demand video helpVOICE PROMPTS
Extensive voice prompts guide user through operation of the unitRESCUE PROTOCOL
AHA/ERC 2010
Supports protocol updates by the user
(password protected)* Typical, with new battery at 25° C
Self Tests
AUTOMATIC
Automatic daily, weekly and monthly circuitry testsBATTERY INSERTION
System integrity test on battery insertionPAD PRESENCE
Pads preconnected tested dailyUSER-INITIATED
Unit and battery pack system test initiated by the userSTATUS INDICATION
Visual and audible indication of unit statusSTATUS SCREEN
Unit self-test results
Pads and battery information
(status and expiration)Patient Analysis System
PATIENT ANALYSIS
Automatically evaluates patient impedance for proper pad contact. Monitors signal quality and analyzes patient ECG for shockable/non-shockable rhythms.SENSITIVITY/SPECIFICITY
Meets AAMI-DF-80 specifications and AHA recommendationsDefibrillation / Monitoring Pads
MODEL
Adult – DDP-2001
Child / Infant – DDP-2002TYPE
Pre-connected, single-use, non-polarized, disposable, self-adhesive electrodes with cable and connectorSURFACE AREA
77 cm2 (nominal, each pad)
50 cm2 (nominal, each pad)Environmental
TEMPERATURE
Operating: 0 to 50°C (32 to 122°F)
Standby: 0 to 50°C (32 to 122°F)RELATIVE HUMIDITY
Operating / Standby: 5%-95%
(non-condensing)ALTITUDE
-500 to 15,000 ft (-150 to 4500m) per MIL-STD-810F 500.4 Procedure llVIBRATION
Ground (MIL-STD-810F 514.5 Category 20)
Helicopter (RTCA/DO-160D, Section 8.8.2, Cat R. Zone 2, Curve G)
Jet Aircraft (RTCA/DO-160D Section 8. Cat H, Zone 2, Curves B & R)SHOCK / DROP ABUSE TOLERANCE
MIL-STD-810F 516.5 Procedure IV 48 inches (1.2 meters), any edge, corner, or surface, in standby modeCRUSH TEST
1,000 pounds (450 kg)SEALING / WATER RESISTANCE
IEC60529 class IP55; Protected against dust and waterjets (battery pack installed)ESD
EN61000-4-2: (Open air up to 8kV or direct contact up to 6kV)EMC (Emission)
CISPR 11 Group 1 Level B
and FCC Part 15EMC (Immunity)
IEC 61000-4-3 and
IEC 61000-4-8Battery Pack
MODEL
DPB-2003 (standard),
DBP-2013 (aviation; TSO C-142a)POWER
12V, 2800 mAhTYPE
Lithium/Manganese Dioxide Disposable, recyclable, non-rechargeableCAPACITY *
125 shocks or 8 hours continuous operationSTANDBY LIFE *
4 yearsLOW BATTERY INDICATORS
Visible
Audible* Typical, with new battery at 25° C
Event Documentation
INTERNAL EVENT RECORD
Critical ECG segments and rescue event parameters are recorded (greater than 60 minutes) and can be downloaded to a removable data cardPC-BASED EVENT REVIEW
ECG with event tag display, and audio playback when availableREMOVABLE STORAGE
(optional) Up to 30 hours of ECG and event data storage (no audio option) or up to 3 hours of audio (audio option). ECG and event storage on a removable data card. Actual length of storage is dependent on card capacity.USB PORT
Event download and maintenance operationsSIZE
7.3 x 9.5 x 2.3 Inches
(18.5 x 24 x 5.8 cm)WEIGHT
Less than 3 lbs (1.4 kg)
(with battery)